Method Development for the Determination of Diacetyl and Acetoin at a Microwave Popcorn Plant

Volume: 38, Issue: 3, Pages: 858 - 861
Published: Dec 11, 2003
Abstract
Separate sampling and analytical methods for the determination of diacetyl and acetoin have been developed to assess workplace exposures at a popcorn processing facility have been described. Diacetyl (NMAM 2557) is efficiently recovered from an Anasorb CMS sampler tube when the composition of methanol in the desorption solvent is 1%, and acetoin (NMAM 2558) is efficiently recovered when the concentration of methanol is increased to 5%....
Paper Details
Title
Method Development for the Determination of Diacetyl and Acetoin at a Microwave Popcorn Plant
Published Date
Dec 11, 2003
Volume
38
Issue
3
Pages
858 - 861