A System Engineering Approach Using FMEA and Bayesian Network for Risk Analysis—A Case Study
Abstract
This paper uses a system engineering approach based on the Failure Mode and Effect Analysis (FMEA) methodology to do risk analysis of the power conditioner of a Proton Exchange Membrane Fuel Cell (PEMFC). Critical components with high risk, common cause failures and effects are identified for the power conditioner system as one of the crucial parts of the PEMFCs used for backup power applications in the telecommunication industry. The results of...
Paper Details
Title
A System Engineering Approach Using FMEA and Bayesian Network for Risk Analysis—A Case Study
Published Date
Dec 20, 2019
Journal
Volume
12
Issue
1
Pages
77 - 77