Aging monitoring of electrical machines using winding high frequency equivalent circuits

Volume: 17, Issue: 1, Pages: 670 - 677
Published: Jan 1, 2019
Abstract
This study defines a monitoring method based on impedance analysis in the upper part of the spectrum. It focuses on the analysis of the high frequency behavior of electrical machines windings considering the turn-to-turn capacitance variations (delta-C) due to insulation aging. An equivalent circuit is automatically generated from the turn arrangements in coils; parameters are computed considering the coil shape and the characteristics of...
Paper Details
Title
Aging monitoring of electrical machines using winding high frequency equivalent circuits
Published Date
Jan 1, 2019
Volume
17
Issue
1
Pages
670 - 677
Citation AnalysisPro
  • Scinapse’s Top 10 Citation Journals & Affiliations graph reveals the quality and authenticity of citations received by a paper.
  • Discover whether citations have been inflated due to self-citations, or if citations include institutional bias.