Transient DC Bias Elimination of Dual-Active-Bridge DC–DC Converter With Improved Triple-Phase-Shift Control

Volume: 67, Issue: 10, Pages: 8587 - 8598
Published: Oct 1, 2020
Abstract
A transient dc-bias current due to the voltage-second imbalance of isolated bidirectional dual-active-bridge (DAB) converters for the disturbance in line or load may result in the transformer saturation and oscillations in both sides dc currents. This article focuses on the transient dc-bias current elimination by using an improved triple-phase-shift (ITPS) control for DAB converters. The inductor peak current stress optimization is adopted in...
Paper Details
Title
Transient DC Bias Elimination of Dual-Active-Bridge DC–DC Converter With Improved Triple-Phase-Shift Control
Published Date
Oct 1, 2020
Volume
67
Issue
10
Pages
8587 - 8598
Citation AnalysisPro
  • Scinapse’s Top 10 Citation Journals & Affiliations graph reveals the quality and authenticity of citations received by a paper.
  • Discover whether citations have been inflated due to self-citations, or if citations include institutional bias.