Treatment performance comparison between regular O3–BAC and O3–BAC with rear sand filtration: verification in a full-scale study

Volume: 31, Issue: 1
Published: Jul 12, 2019
Abstract
To improve the microbial safety of drinking water, an arrangement of O3-BAC with rear sand filtration (O3-BAC-sand) has been proposed. In this study, efforts were devoted to evaluate the benefits and drawbacks of O3-BAC-sand in a full-scale water treatment plant. The performance of the two configurations was compared in terms of particles, turbidity, CODMn and typical odorants and pesticides.The O3-BAC-sand yielded lower turbidity but higher...