Surface analysis on revised hip implants with stem taper for wear and failure incidence evaluation: A first investigation

Published on Oct 1, 2019in Measurement2.791
· DOI :10.1016/J.MEASUREMENT.2019.05.097
Saverio Affatato26
Estimated H-index: 26
,
Alessandro Ruggiero17
Estimated H-index: 17
(UNISA: University of Salerno)
Sources
Abstract
Abstract Background As revision surgeries of total hip arthroplasty are going to increase, success or failure of revised implants is a fundamental aspect in the orthopaedic field. Today, slight is known about the success rate of revised total hip arthroplasty when the femoral head is substituted on a retained stem. Question We wanted to investigate if the interposition of a stem taper adapter between the paired elements can influence this rate of success. Methods From a total of more than 1000 revised implants, recorded during their follow up in a regional registry, the study was limited to the ones subjected to a surgical revision, where the head has been revised but the stem taper has not. Investigations on wear, roughness, and corrosion on the available explants were conducted, with the aim of providing visual and empirical response on the topic and to furnish to other researches useful data for comparison. Results Our results highlighted a higher incidence of second revisions when the femoral head is substituted without using an adapter. The topographic analysis refers that it is not evident a predominant roughness along any of the stems directions: no evidences were found that would define a recurrent rougher direction. This indicates a homogeneous worsening or corrosion of the stem taper along the circumference. Further, we found that the roughness values of the specimens analyzed not influence their surfaces and there is no a direct relation between the roughness of the bore heads and the stem tapers.
  • References (52)
  • Citations (4)
📖 Papers frequently viewed together
2014
7 Authors (Ashley K Matthies, ..., A. J. Hart)
2 Citations
17 Citations
78% of Scinapse members use related papers. After signing in, all features are FREE.
References52
Newest
#1Saverio AffatatoH-Index: 26
#2Massimiliano MerolaH-Index: 13
Last. Alessandro Ruggiero (UNISA: University of Salerno)H-Index: 17
view all 3 authors...
Abstract Background Total replacement of the knee joint is a well-established surgical procedure performed to relieve pain and to restore the functionality of a compromised knee. Nevertheless, wear is still one of the main issues affecting joint prostheses, causing loosening and, eventually, implants failure. Surface roughness of the implant has been found to influence the mechanisms for premature wear, having relevant influence on the tribological performance. Question Joint load distribution h...
9 CitationsSource
#2Paolo EraniH-Index: 9
Last. Aldo ToniH-Index: 32
view all 4 authors...
Co alloy modular necks have been introduced in orthopaedics to address mechanical failure of the neck-stem junction (NSJ) observed in Ti alloy dual-modular hip stem. However, following the introduc...
1 CitationsSource
#1Annika Krull (TUHH: Hamburg University of Technology)H-Index: 3
#2Michael M. Morlock (TUHH: Hamburg University of Technology)H-Index: 43
Last. Nicholas E. Bishop (Hamburg University of Applied Sciences)H-Index: 19
view all 3 authors...
Abstract Background Intraoperative interface contamination of modular head-stem taper junctions of hip implants can lead to poor fixation strength, causing fretting and crevice corrosion or even stem taper fracture. Careful cleaning before assembly should help to reduce these problems. The purpose of this study was to determine the effect of cleaning (with and without drying) contaminated taper interfaces on the taper fixation strength. Methods Metal or ceramic heads were impacted onto titanium ...
12 CitationsSource
#2Paolo EraniH-Index: 9
Last. Susanna SteaH-Index: 26
view all 8 authors...
Recently, concerns have been raised about the potential effect of head-neck junction damage products at the local and systemic levels. Factors that may affect this damage process have not been fully established yet. This study investigated the possible correlations among head-neck junction damage level, implant design, material combination, and patient characteristics. Head-neck junctions of 148 retrieved implants were analysed, including both ceramic-on-ceramic (N = 61) and metal-on-metal (N = ...
5 CitationsSource
#1Chelsea N. Koch (HSS: Hospital for Special Surgery)H-Index: 6
#2Mark P. Figgie (HSS: Hospital for Special Surgery)H-Index: 32
Last. Douglas E. Padgett (HSS: Hospital for Special Surgery)H-Index: 34
view all 6 authors...
Background The BIOLOX® option system, consisting of a BIOLOX® delta ceramic femoral head with a titanium alloy adapter sleeve, is being increasingly utilized in revision hip arthroplasty. The sleeve protects the ceramic head from fracture and improper motion about the stem trunnion when a damaged trunnion is encountered at revision surgery. Corrosion and fretting due to metal-metal contact at the taper region of hip prosthesis create the potential of causing periprosthetic osteolysis and adverse...
9 CitationsSource
#1Paola Taddei (UNIBO: University of Bologna)H-Index: 36
#2Silvia Tozzi (UNIBO: University of Bologna)H-Index: 11
Last. Saverio AffatatoH-Index: 26
view all 4 authors...
This study was aimed at determining the surface degradation occurred on retrieved ceramic and metallic heads, as well as the influence of the head surface quality on the wear of the polyethylene counterface. To this purpose, 14 ceramic and 14 metallic femoral heads retrieved at revision surgery were examined. Scanning electron microscopic analysis provided visual evidence that some metallic heads presented crescent wear more often than the ceramic ones; the former showed a higher volumetric loss...
4 CitationsSource
#1Alisdair MacLeod (University of Bath)H-Index: 6
#2Niall Sullivan (North Bristol NHS Trust)H-Index: 4
Last. Harinderjit Gill (University of Bath)H-Index: 52
view all 4 authors...
Objectives Modular junctions are ubiquitous in contemporary hip arthroplasty. The head-trunnion junction is implicated in the failure of large diameter metal-on-metal (MoM) hips which are the currently the topic of one the largest legal actions in the history of orthopaedics (estimated costs are stated to exceed $4 billion). Several factors are known to influence the strength of these press-fit modular connections. However, the influence of different head sizes has not previously been investigat...
12 CitationsSource
#1Saverio AffatatoH-Index: 26
#2Alessandro Ruggiero (UNISA: University of Salerno)H-Index: 17
Last. Paola Taddei (UNIBO: University of Bologna)H-Index: 36
view all 4 authors...
Abstract Although metal transfer (MTR) has been observed in total hip replacement, little is known about its effects on the wear phenomena of bearing surface materials. This study was aimed at investigating the effects of MTR on the bearing surface of zirconia and Biolox® Delta ceramic femoral heads, to identify prevalent surface patterns and morphologies as well as to evaluate possible phase changes upon MTR, assessing the monoclinic zirconia content and quantifying the tetragonal → monoclinic ...
23 CitationsSource
#1Timothy McTigheH-Index: 2
#2Declan BrazilH-Index: 4
Last. Edward J. McPhersonH-Index: 4
view all 5 authors...
The emergence of modularity in total hip arthroplasty (THA) in the 1980s and 1990s was based on the fact that the benefit of these design features outweighed the risk. The use of metallic modular junctions presents a unique set of advantages and problems for use in THA. The advantages include improvement in fit and fill of the implant to bone, restoration of joint mechanics, reduced complications in revision surgery and reduction of costly inventory. However, the risks or concerns are a little h...
8 CitationsSource
#1Julian Gührs (TUHH: Hamburg University of Technology)H-Index: 4
#2Annika Krull (TUHH: Hamburg University of Technology)H-Index: 3
Last. Michael M. Morlock (TUHH: Hamburg University of Technology)H-Index: 43
view all 4 authors...
Abstract Ceramic components are frequently used in total hip replacement due to their good tribological properties. In revision of broken ceramic heads clinical uncertainties arise, whether the taper of the stem can be re-used with a new ceramic head, especially if the stem is well fixed. Ceramic is a brittle material. Even small damage on the male stem taper can lead to stress concentrations causing premature failure of a new ceramic head. As a consequence, manufactures strictly prohibit stem t...
15 CitationsSource
Cited By4
Newest
#1A. Gogolin (Opole University of Technology)
#2M. Wasilewski (Opole University of Technology)
Last. Grzegorz Krolczyk (Opole University of Technology)H-Index: 33
view all 8 authors...
Abstract This paper focuses on evaluation of differences in the newly manufactured U-tubes and ones after operation. Differences in geometry and internal surface roughness were investigated and a flow simulation was carried out in the Ansys Fluent software, where properties such as flow nature, maximum velocity and pressure drop were examined. A numerical model validation process was carried out with an application of PIV experiments. The digital models of the U-tube were obtained with an applic...
Source
#1Wojciech Kacalak (Koszalin University of Technology)H-Index: 11
#2D. Lipiński (Koszalin University of Technology)H-Index: 6
Last. Grzegorz Krolczyk (Opole University of Technology)H-Index: 33
view all 6 authors...
Abstract This paper presents a methodology for assessing the state of the active surface of abrasive tools using new parameters that characterize their machining potential. The new parameters were defined in consideration of the features of abrasive tools, which resulted from the variability of the arrangement of the ridges of abrasive grains and the diversity of their shape and orientation. A detailed analysis was performed to determine the impact of the protrusion, sharpness, and cutting edge ...
Source
#1Becan Lawless (University of Manchester)
#2Robert Heinemann (University of Manchester)H-Index: 7
Last. Amer Liaqat (EADS: Airbus)
view all 3 authors...
Abstract Tapered interference-fit fasteners (e.g. Taper-lok) are commonly used by the aerospace industry due to their high fatigue strength. The inspection relies on a ‘true’ geometry gauge coated with a thin film of engineer’s blue being brought firmly into contact with the tapered hole. The pattern created on the gauge is then used to identify bearing surface area and distribution. This research investigates if the inspection reflects the hole geometry, and under what conditions the inspection...
Source
The need for metallic biomaterials will always remain high with their growing demand in joint replacement in the aging population. This creates need for the market and researchers to focus on the development and advancement of the biometals. Desirable characteristics such as excellent biocompatibility, high strength, comparable elastic modulus with bones, good corrosion resistance, and high wear resistance are the significant issues to address for medical implants, particularly load-bearing orth...
2 CitationsSource