Behavior of Interconnect-Failed PV Modules Under Standard Test Conditions and Actual Operation Conditions

Volume: 8, Issue: 6, Pages: 1761 - 1766
Published: Nov 1, 2018
Abstract
Comparisons of indoor measurements under standard test conditions (STC) and outdoor measurements under actual operation conditions of ten-year-used interconnect-failed PV modules were described. In the indoor measurements under STC, no sample modules showed the output power degradation of more than 20% from the rated power. In the outdoor measurements of the sample modules, the open-circuit voltage decreased in a discrete value with a half volt...
Paper Details
Title
Behavior of Interconnect-Failed PV Modules Under Standard Test Conditions and Actual Operation Conditions
Published Date
Nov 1, 2018
Volume
8
Issue
6
Pages
1761 - 1766
Citation AnalysisPro
  • Scinapse’s Top 10 Citation Journals & Affiliations graph reveals the quality and authenticity of citations received by a paper.
  • Discover whether citations have been inflated due to self-citations, or if citations include institutional bias.