Sensitization in Aluminum Alloys: Effect on Acoustic Parameters

Volume: 74, Issue: 11, Pages: 1237 - 1244
Published: Aug 15, 2018
Abstract
Velocity and attenuation of shear and longitudinal sound waves were measured as a function of sensitization level in AA5083-H116 and AA5456-H116 aluminum alloys using two different techniques: resonant ultrasound spectroscopy (RUS) and pulse echo (PE). The frequency range for RUS was 0.3 MHz to 1 MHz. For PE, longitudinal 3.5 MHz and shear 1 MHz transducers were used. Sensitization was artificially induced in the laboratory by isothermally...
Paper Details
Title
Sensitization in Aluminum Alloys: Effect on Acoustic Parameters
Published Date
Aug 15, 2018
Journal
Volume
74
Issue
11
Pages
1237 - 1244
Citation AnalysisPro
  • Scinapse’s Top 10 Citation Journals & Affiliations graph reveals the quality and authenticity of citations received by a paper.
  • Discover whether citations have been inflated due to self-citations, or if citations include institutional bias.