Long-term district-scale geothermal exchange borefield monitoring with fiber optic distributed temperature sensing
Abstract
Fiber optic (FO) distributed temperature sensing (DTS) was used for long-term monitoring of a 280-m by 360-m geothermal exchange borefield with 2596 boreholes to quantify the role of groundwater flow and thermophysical properties on subsurface heat transfer and storage. Most district-scale borefields are subject to a sustained imbalance in heating or cooling loads and experience yearly subsurface temperature increases that may, without...
Paper Details
Title
Long-term district-scale geothermal exchange borefield monitoring with fiber optic distributed temperature sensing
Published Date
Mar 1, 2018
Journal
Volume
72
Pages
193 - 204