DESIGN AND THERMAL ASPECTS OF WATER COOLED PRIMARY MIRROR FOR SYNCHROTRON RADIATION

Published: Jan 1, 2014
Abstract
This paper describes the thermal analysis of water cooled primary mirror used in BL-23 of Indus-2 at RRCAT in which the mirror thermal deformation was minimized for acceptable optical performance. The primary mirror separates the visible part from synchrotron radiation by reflecting visible part to perpendicular plane. In worst condition the primary mirror will be subjected to intense heat load of 150 W, primarily due to X-Ray absorption. This...
Paper Details
Title
DESIGN AND THERMAL ASPECTS OF WATER COOLED PRIMARY MIRROR FOR SYNCHROTRON RADIATION
Published Date
Jan 1, 2014
Citation AnalysisPro
  • Scinapse’s Top 10 Citation Journals & Affiliations graph reveals the quality and authenticity of citations received by a paper.
  • Discover whether citations have been inflated due to self-citations, or if citations include institutional bias.