Determination of 4-hydroxy-2-nonenal in primary rat hepatocyte cultures by liquid chromatography with laser induced fluorescence detection
Abstract
An HPLC (high performance liquid chromatography) method with laser induced fluorescence (LIF) detection is described for the determination of 4-hydroxy-2-nonenal (HNE) formed from lipid peroxidation in rat hepatocytes. Carbonyl compounds were fluorescently labelled by incubating the hepatocyte samples with a tagging reagent, 4-(2-carbazoylpyrrolidin-1-yl)-7-nitro-2,1,3-benzoxadiazole (NBD-ProCZ), at 60°C for 10 min. The hydrazone derivatives...
Paper Details
Title
Determination of 4-hydroxy-2-nonenal in primary rat hepatocyte cultures by liquid chromatography with laser induced fluorescence detection
Published Date
Feb 1, 1999
Journal
Volume
13
Issue
1
Pages
75 - 80