Abstract The bottom ash cooler is an important auxiliary equipment of a circulating fluidized bed (CFB) boiler. As the CFB boiler technology develops, the rotary ash coolers have partially substituted the fluidized bed bottom ash coolers in the industrial practice due to its excellent reliability. To meet the increased output requirement, a double-cylinder rotary ash cooler, rather than the conventional single-cylinder one, was proposed in the present study. This paper provided the design of the...
Source
#1Yuge Yao (THU: Tsinghua University)H-Index: 1
#2Runxia Cai (THU: Tsinghua University)H-Index: 6
Last. Junfu Lyu (THU: Tsinghua University)H-Index: 6
view all 6 authors...
Abstract It is very important to accurately measure the tube-wall temperature of the high-temperature heating surface in the boilers with high steam parameters such as supercritical circulating fluidized bed (CFB) boilers. However, the severe abrasion problem caused by high solid concentration in CFB boilers hinders a direct tube-wall temperature measurement in CFB boilers. In this paper, a new method which embeds thermocouples in deposited metal on the heating surface was proposed to solve this...