Xu Liu
Northwest University (United States)
Analytical chemistryMass spectrometryIsotopeInductively coupled plasma mass spectrometryIsotope analysis
5Publications
5H-index
84Citations
What is this?
Publications 5
Newest
#1Honglin Yuan (Northwest University (United States))H-Index: 37
#1YUANHonglin (Northwest University (United States))H-Index: 1
Last. Johnson Wenhong Qiu (HKU: University of Hong Kong)H-Index: 1
view all 8 authors...
Abstract We herein report the coupling of a nanosecond laser ablation system with a large-scale multi-collector inductively coupled plasma mass spectrometer (Nu1700 MC-ICPMS, NP-1700) and a conventional Nu Plasma II MC-ICPMS (NP-II) for the simultaneous laser ablation and determination of in situ S and Pb isotopic compositions of sulfide minerals. We found that the required aerosol distribution between the two spectrometers depended on the Pb content of the sample. For example, for a sulfide con...
17 CitationsSource
#1Honglin Yuan (Northwest University (United States))H-Index: 37
#1YUANHonglin (Northwest University (United States))H-Index: 1
Last. Chunlei Zong (Northwest University (United States))H-Index: 7
view all 5 authors...
High-purity N2 was used to increase the mobile phase flow rate during ion purification of ion-exchange resin. This was performed to improve the efficiency of isotope separation and purification, and to meet the efficiency requirements of rapid multiple-collector-inductively coupled plasma mass spectrometry (MC-ICPMS) analysis. For Cu isotope separation, our results indicated that at a gas flow rate >60 mL/min, the separation chromatographic peaks broadened and the recovery rate decreased to 99.9...
5 CitationsSource
#1YUANHonglin (Northwest University (United States))H-Index: 1
#1Honglin Yuan (Northwest University (United States))H-Index: 37
Last. Shaocong Lai (Northwest University (United States))H-Index: 22
view all 10 authors...
Abstract Because Pb isotopes can be used for tracing, they are widely used in many disciplines. The detection and analysis of Pb isotopes of bulk samples are usually conducted using thermal ionization mass spectrometer (TIMS) and multiple-collector inductively coupled plasma mass spectrometer (MC-ICP-MS), both of which need external reference materials with known isotopic compositions to correct for the mass discrimination effect produced during analysis. NIST NBS 981 is the most widely used ref...
10 CitationsSource
#1Zhian Bao (Northwest University (United States))H-Index: 9
#2Wenting Yuan (Northwest University (United States))H-Index: 2
Last. Chunlei Zong (Northwest University (United States))H-Index: 7
view all 6 authors...
Abstract In this study, lead isotopic ratios in bronze artifacts were non-matrix-matched determined directly by femtosecond laser ablation multi-collector inductively coupled plasma mass spectrometry (fsLA-MC-ICP-MS). We evaluated the necessity of matrix matching for lead isotope ratio analyses of bronzes by adopting thallium solution to correct mass discrimination during mass spectrometer measurements. Lead isotope ratios of four bronze reference materials were measured by fsLA-MC-ICP-MS to det...
22 CitationsSource
#1Honglin Yuan (Northwest University (United States))H-Index: 37
#1YUANHonglin (Northwest University (United States))H-Index: 1
Last. Shao-Yong Jiang (China University of Geosciences)H-Index: 46
view all 10 authors...
An in-situ microanalysis of Pb isotopic compositions in sulfide minerals is carried out by using femtosecond laser-ablation multi-collector inductively coupled plasma mass spectrometry (fsLA-MC-ICP-MS). High-temperature-activated carbon was used to filter Hg contained in the carrier gas, which reduced the Hg background signal by 48% and also lowered the detection limit of the analysis. Fractionation and mass discrimination effects existing in the ICP-MS analytical processes were corrected using ...
30 CitationsSource