Chunlei Zong
Northwest University (United States)
Analytical chemistryIsotopeInductively coupled plasma mass spectrometryChemistryIsotope analysis
24Publications
7H-index
758Citations
What is this?
Publications 22
Newest
#1Yan Zhang (Northwest University (United States))H-Index: 1
#2Zhian Bao (Northwest University (United States))H-Index: 9
Last. YUANHonglin (Northwest University (United States))H-Index: 1
view all 6 authors...
This study performed a series of comparable experiments (with or without column chromatography) to assess whether non-deviated Cu isotope ratios can be acquired directly by Nu Plasma II multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) using standard-sample bracketing with Ga as internal mass bias correction model (C-SSBIN) without column chromatography. Twelve Cu-dominated minerals (copper plate, native copper, chalcopyrite, bornite, chalcocite, digenite, covellite, tetra...
Source
#1Zhian Bao (Northwest University (United States))H-Index: 9
#2Chunlei Zong (Northwest University (United States))H-Index: 7
Last. Honglin Yuan (Northwest University (United States))H-Index: 37
view all 6 authors...
This study presents a practical method for high-precision Cu and Pb isotope determination without column chemistry for bronzes using MC-ICP-MS. The standard-sample bracketing method combined with Ga internal normalization (SSBIN) is used to correct the instrumental mass bias during Cu isotopic analysis. The effects of acidity mismatch, concentration mismatch and matrix effect were rigorously evaluated using Nu Plasma II MC-ICP-MS in a wet plasma mode. The precision and accuracy of this method were...
2 CitationsSource
#1Zhian Bao (Northwest University (United States))H-Index: 9
#2Chunlei Zong (Northwest University (United States))H-Index: 7
Last. YUANHonglin (Northwest University (United States))H-Index: 1
view all 5 authors...
Abstract This study presented a chemical protocol for purification of calcium and magnesium from a single aliquot of biological and geological samples. The separation protocol was based on a two-step cation exchange chromatography using DGA resin and AG50W-X12 (200–400 mesh) resin. Calcium fraction was first collected using 0.25 mL of DGA resin, and Mg fraction was then collected using 0.5 mL of AG50W-X12 cation exchange resin. For Ca isotope analysis, the effect of acidity and concentration mis...
2 CitationsSource
#1Lu Chen (Northwest University (United States))H-Index: 4
#2Zhian Bao (Northwest University (United States))H-Index: 9
Last. Chunlei Zong (Northwest University (United States))H-Index: 7
view all 5 authors...
In sample preparation and mass spectrometry analysis, sample dissolution, column chemistry, concentration mismatches, and matrix effects have significant potential for introducing analytical artifacts during Mg isotope analysis. Based on the low MgO content and undesirable matrix elements in felsic rocks, the development of well-characterized felsic standards is essential to reduce inter-laboratory mass bias, enable the assessment of data accuracy, and facilitate the comparison of chemical separ...
Source
#1Zhian Bao (Northwest University (United States))H-Index: 9
#2Chunlei Zong (Northwest University (United States))H-Index: 7
Last. YUANHonglin (Northwest University (United States))H-Index: 1
view all 6 authors...
This study presents a practical method for high-precision Mg isotope determination without column chromatography for carbonate samples using sulphuric acid and MC-ICP-MS. The protocol uses the chemical reaction between carbonate and sulphuric acid to generate CaSO4 precipitation and MgSO4 supernatant, which is used to determine Mg isotopic ratios. The matrix effects and the sulphuric acid conditions were rigorously examined using Nu Plasma II with a wet plasma mode. The precision and accuracy of...
1 CitationsSource
#1YUANHonglin (Northwest University (United States))H-Index: 1
#2Zhian Bao (Northwest University (United States))H-Index: 9
Last. Tao Zhang (Northwest University (United States))
view all 6 authors...
In this work, we improved the sensitivity of a multi-collector-inductively coupled plasma mass spectrometry system by increasing the vacuum of the expansion chamber using a high-speed EH mechanical booster pump (EH500, 500 m3 h−1, BOC Edwards) in conjunction with a standard E2M80 pump (80 m3 h−1, BOC Edwards). The vacuum was improved from 1.0 mbar to less than 0.5 mbar. The sample ion yield for heavy isotopes, such as those of Pb, was improved from 0.047% to 0.072% in the wet-plasma mode (sample...
Source
#1Zhian Bao (Northwest University (United States))H-Index: 9
#2Kangjun Huang (Northwest University (United States))H-Index: 12
Last. YUANHonglin (Northwest University (United States))H-Index: 1
view all 7 authors...
This study presents a chemical protocol for the separation of Mg that is particularly adapted for diverse igneous rock samples, especially for high-K and low-Mg rocks. This protocol is based on a combination of three procedures: the removal of K from the samples using the precipitation procedure, followed by the separation of Fe and Ca using 2 mL of AG50W-X12 cation exchange resin, and finally the removal of Al, Ti, Na, and Fe elements using 0.5 mL of AG50W-X12 cation exchange resin. The effect ...
6 CitationsSource
#1Zhian Bao (Northwest University (United States))H-Index: 9
#2Chunlei Zong (Northwest University (United States))H-Index: 7
Last. YUANHonglin (Northwest University (United States))H-Index: 1
view all 6 authors...
In this study, Pb isotope ratios in ferromanganese nodules were determined with good repeatability and minimum laboratory bias using laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS). One certified ferromanganese nodule reference material, NOD-A-1, in the form of pressed powder pellets (PPPs) produced upon ultrafine processing, was homogeneous enough to be used as an in-house matrix-matched standard or quality control sample for Pb isotopic microanalysis....
1 CitationsSource
#1Chunlei Zong (Northwest University (United States))H-Index: 7
#2Zhian Bao (Northwest University (United States))H-Index: 9
Last. YUANHonglin (Northwest University (United States))H-Index: 1
view all 7 authors...
Herein, the potential of laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) for the determination of Pb isotopes of lead-glazed ceramics has been investigated. To obtain good precision and accuracy, thallium was adopted to correct mass bias during Pb isotope analyses. The average 206Pb/204Pb, 207Pb/204Pb, 208Pb/204Pb, 207Pb/206Pb, and 208Pb/206Pb ratios determined by LA-MC-ICP-MS were within 0.027% of that obtained by the solution nebulizer MC-ICP-MS (SN-M...
2 CitationsSource
#1Zhian Bao (Northwest University (United States))H-Index: 9
#2Chunlei Zong (Northwest University (United States))H-Index: 7
Last. Mengning Dai (Northwest University (United States))H-Index: 6
view all 6 authors...
In this study, we established a rapid acid digestion for determining Hf–Sr–Nd isotopic ratios of geological samples by using MC-ICP-MS. Conditions of 1600 °C for 1 min and 1400 °C for 1 min were adopted for fusing intrusive rocks and extrusive rocks, respectively. The rapid acid digestion technique is superior in digestion time compared with high-pressure PTFE bomb method. The procedural blanks of the method were also lower than that flux fusion. Replicate analyses of international certified ref...
4 CitationsSource